| Article number | 6GK7443-1GX30-0XE0 |
| Product type designation | CP 443-1 Advanced |
| Transfer rate | |
| Transfer rate | |
|
● at the 1st interface
|
10 … 1 000 Mbit/s |
|
● at the 2nd interface
|
10 … 100 Mbit/s |
| Interfaces | |
| Number of interfaces acc. to Industrial Ethernet | 5 |
| Number of electrical connections | |
|
● at the 1st interface acc. to Industrial Ethernet
|
1 |
|
● at the 2nd interface acc. to Industrial Ethernet
|
4 |
| Type of electrical connection | |
|
● at the 1st interface acc. to Industrial Ethernet
|
RJ45 port |
|
● at the 2nd interface acc. to Industrial Ethernet
|
RJ45 port |
| design of the removable storage C-PLUG | Yes |
| Supply voltage, current consumption, power loss | |
| Type of voltage of the supply voltage | DC |
| Supply voltage 1 from backplane bus | 5 V |
| Relative symmetrical tolerance at DC | |
|
● at 5 V
|
5 % |
| Consumed current | |
|
● from backplane bus at DC at 5 V typical
|
1.8 A |
| Power loss [W] | 9 W |
| Ambient conditions | |
| Ambient temperature | |
|
● during operation
|
0 … 60 °C |
|
● during storage
|
-40 … +70 °C |
|
● during transport
|
-40 … +70 °C |
| Relative humidity | |
|
● at 25 °C without condensation during operation maximum
|
95 % |
| Protection class IP | IP20 |
| Design, dimensions and weights | |
| Module format | Compact module S7-400 single width |
| Width | 25 mm |
| Height | 290 mm |
| Depth | 210 mm |
| Net weight | 0.7 kg |
| Product features, product functions, product components general | |
| Number of units | |
|
● per CPU maximum
|
14 |
|
● Note
|
max. 4 as PN IO ctrl. |
| Performance data open communication | |
| Number of possible connections for open communication by means of SEND/RECEIVE blocks maximum | 64 |
| Amount of data | |
|
● as user data per ISO connection for open communication by means of SEND/RECEIVE blocks maximum
|
8 Kibyte |
|
● as user data per ISO on TCP connection for open communication by means of SEND/RECEIVE blocks maximum
|
8 Kibyte |
|
● as user data per TCP connection for open communication by means of SEND/RECEIVE blocks maximum
|
8 Kibyte |
|
● as user data per UDP connection for open IE communication by means of SEND/RECEIVE blocks maximum
|
2 Kibyte |
| Number of possible connections for open communication | |
|
● by means of T blocks maximum
|
64 |
| Amount of data | |
|
● as user data per ISO on TCP connection for open communication by means of T blocks maximum
|
1 452 byte |
| Performance data S7 communication | |
| Number of possible connections for S7 communication | |
|
● maximum
|
128; when using several CPUs |
|
● with PG connections maximum
|
2 |
| Performance data multi-protocol mode | |
| Number of active connections with multi-protocol mode | 128 |
| Performance data IT functions | |
| Number of possible connections | |
|
● as client by means of FTP maximum
|
20 |
|
● as server by means of FTP maximum
|
10 |
| Number of possible connections | |
|
● as server by means of HTTP maximum
|
4 |
|
● as e-mail client maximum
|
1 |
| Amount of data as user data for email maximum | 8 Kibyte |
| Storage capacity of the user memory | |
|
● as flash memory file system
|
30 Mibyte |
|
● as RAM
|
16 Mibyte |
|
● additionally buffered as RAM via central backup battery
|
512 Kibyte |
| Number of possible write cycles of the flash memory cells | 100 000 |
| Performance data PROFINET communication as PN IO controller | |
| Product function PROFINET IO controller | Yes |
| Number of PN IO devices on PROFINET IO controller usable total | 128 |
| Number of PN IO IRT devices on PROFINET IO controller usable | 64 |
| Number of external PN IO lines with PROFINET per rack | 4 |
| Amount of data | |
|
● as user data for input variables as PROFINET IO controller maximum
|
4 Kibyte |
|
● as user data for input variables as PROFINET IO controller maximum
|
4 Kibyte |
|
● as user data for input variables per PN IO device as PROFINET IO controller maximum
|
1 433 byte |
|
● as user data for output variables per PN IO device as PROFINET IO controller maximum
|
1 433 byte |
|
● as user data for input variables per PN IO device for each sub-module as PROFINET IO controller maximum
|
240 byte |
|
● as user data for output variables per PN IO device for each sub-module as PROFINET IO controller maximum
|
240 byte |
| Performance data PROFINET CBA | |
| Number of remote connection partners with PROFINET CBA | 64 |
| Number of connections with PROFINET CBA total | 600 |
| Amount of data | |
|
● as user data for digital inputs with PROFINET CBA maximum
|
8 Kibyte |
|
● as user data for digital outputs with PROFINET CBA maximum
|
8 Kibyte |
|
● as user data for arrays and data types in the case of acyclic transmission with PROFINET CBA maximum
|
8 Kibyte |
|
● as user data for arrays and data types with PROFINET CBA with cyclical transfer maximum
|
250 byte |
|
● as user data for arrays and data types with PROFINET CBA in the case of local interconnection maximum
|
2 400 byte |
| Performance data PROFINET CBA remote interconnection with acyclic transfer | |
| Refresh time of the remote interconnections in the case of acyclic transmission with PROFINET CBA | 100 ms |
| Number of remote connections to input variables in the case of acyclic transmission with PROFINET CBA maximum | 150 |
| Number of remote connections to output variables in the case of acyclic transmission with PROFINET CBA maximum | 150 |
| Amount of data | |
|
● as user data for remote interconnections with input variables in the case of acyclic transmission with PROFINET CBA
|
8 Kibyte |
|
● as user data for remote interconnections with output variables in the case of acyclic transmission with PROFINET CBA
|
8 Kibyte |
| Performance data PROFINET CBA remote interconnection with cyclic transfer | |
| Refresh time of the remote interconnections with PROFINET CBA with cyclical transfer | 10 ms |
| Number of remote connections to input variables with PROFINET CBA with cyclical transfer maximum | 250 |
| Number of remote connections to output variables with PROFINET CBA with cyclical transfer maximum | 250 |
| Amount of data | |
|
● as user data for remote interconnections with input variables with PROFINET CBA with cyclical transfer maximum
|
2 000 byte |
|
● as user data for remote interconnections with output variables with PROFINET CBA with cyclical transfer maximum
|
2 000 byte |
| Performance data PROFINET CBA HMI variables via PROFINET acyclic | |
| Number of connectable HMI stations for HMI variables in the case of acyclic transmission with PROFINET CBA | 3 |
| Refresh time of the HMI variables in the case of acyclic transmission with PROFINET CBA | 500 ms |
| Number of HMI variables in the case of acyclic transmission with PROFINET CBA maximum | 200 |
| Amount of data as user data for HMI variables in the case of acyclic transmission with PROFINET CBA maximum | 8 Kibyte |
| Performance data PROFINET CBA device-internal interconnections | |
| Number of internal connections with PROFINET CBA maximum | 300 |
| Amount of data of the internal connections with PROFINET CBA maximum | 2 400 byte |
| Performance data PROFINET CBA interconnections to constants | |
| Number of connections with constants with PROFINET CBA maximum | 500 |
| Amount of data as user data for interconnections with constants with PROFINET CBA maximum | 4 000 byte |
| Performance data PROFINET CBA PROFIBUS proxy functionality | |
| Product function with PROFINET CBA PROFIBUS proxy functionality | No |
| Product functions management, configuration, engineering | |
| Product function MIB support | Yes |
| Protocol is supported | |
|
● SNMP v1
|
Yes |
|
● SNMP v3
|
Yes |
|
● DCP
|
Yes |
|
● LLDP
|
Yes |
| Configuration software | |
|
● required
|
STEP 7 V5.5 SP3 or higher / STEP 7 Professional V12 (TIA Portal) or higher |
|
● for PROFINET CBA required
|
SIMATIC iMap V3.0 SP1 and higher |
| Product functions Diagnostics | |
| Product function Web-based diagnostics | Yes |
| Product functions Switch | |
| Product feature Switch | Yes |
| Product function | |
|
● switch-managed
|
No |
|
● with IRT PROFINET IO switch
|
Yes |
|
● Configuration with STEP 7
|
Yes |
| Product functions redundancy | |
| Product function | |
|
● Ring redundancy
|
Yes |
|
● Redundancy manager
|
Yes |
| Protocol is supported Media Redundancy Protocol (MRP) | Yes |
| Product functions Security | |
| Firewall version | stateful inspection |
| Product function with VPN connection | IPSec |
| Type of encryption algorithms with VPN connection | AES-256, AES-192, AES-128, 3DES-168, DES-56 |
| Type of authentication procedure with VPN connection | Preshared key (PSK), X.509v3 certificates |
| Type of hashing algorithms with VPN connection | MD5, SHA-1 |
| Number of possible connections with VPN connection | 32 |
| Product function | |
|
● password protection for Web applications
|
Yes |
|
● ACL – IP-based
|
Yes |
|
● ACL – IP-based for PLC/routing
|
Yes |
|
● switch-off of non-required services
|
Yes |
|
● Blocking of communication via physical ports
|
Yes |
|
● log file for unauthorized access
|
No |
| Product functions time | |
| Product function SICLOCK support | Yes |
| Product function pass on time synchronization | Yes |
| Protocol is supported | |
|
● NTP
|
Yes |