| Type designations | TF1- _ _ _ _-001 – 41 _ – 102
Voltage |
TF1- _ _ _ _-001 – 42 _ – 102
Current |
| Electrical Data | ||
| Electrical measuring range (dimension B) | 0100 up to 1000 | mm |
| Output signal | 0,1 … 10 V (load > 5 kΩ) | 4 … 20 mA (burden < 500 Ω) |
| Number of channels | 1 | |
| Update rate (internal) | > 10 | kHz |
| Signal propagation delay | < 1 | ms |
| Resolution
Dimension B < 400 mm Dimension B > 400 mm |
10 20 |
µm µm |
| Absolute linearity | < 0.025 (min. ± 100 µm) | ±% FS |
| Tolerance of electr. zero point | 1 | ± mm |
| Reproducibility Dimension B < 400 mm Dimension B > 400 mm |
10 20 |
µm µm |
| Hysteresis | < 10 | µm |
| Temperature error | < 15 (min. 0.01 mm/K) | ppm/K |
| Supply voltage | 24 (18 … 32) | VDC |
| Supply voltage ripple | < 10 | % Vss |
| Power drain (w/o load) | 2.4 | W |
| Overvoltage protection | 36 (permanent) | VDC |
| Polarity protection | Yes, up to supply voltage max | VDC |
| Short circuit protection | Yes (outputs vs. GND and supply voltage max.) | |
| Insulation resistance (500 VDC) | > 10 | MΩ |
| Environmental Data | ||
| MTTF (DIN EN ISO 13849-1
parts count method, w/o load, wc) |
> 20 | Years |
| Novotechnik Analog | TF1-0800-001-411-102 | TF1-0800-001-421-102 |
| Novotechnik Analog | TF1-0800-001-413-102 | TF1-0800-001-422-102 |
| Novotechnik Analog | TF1-0800-001-414-102 | TF1-0800-001-423-102 |
| Novotechnik Analog | TF1-0800-001-424-102 | |