| Model | GT2-S1 | GT2-S5 |
| Detection system | Differential transformer | |
| Measuring range*1 | 1 mm 0.04″ | 5 mm 0.20″ |
| Operating range*1 | 2 mm 0.08″ | 7 mm 0.28″ |
| Resolution | 0.1 μm | |
| Indicated accuracy*2 *4 | 1 μm (P-P) | |
| Measuring force*3Downward mounting | 1.12 N | 1.0 N |
| Side mounting | 1.1 N | 0.95 N |
| Upward mounting | 1.08 N | 0.9 N |
| Sampling cycle | 1 ms | |
| Mechanical response*4 | 40 Hz | 20 Hz |
| Operation indicator light | 2-color LED (red, green) | |
|
Environmental resistance Enclosure rating |
IP67G(JIS)*5 IP67(IEC) | |
| Ambient temperature | -10 to +55°C 14 to 131°F (No freezing) | |
| Relative humidity | 10 to 85% RH (No condensation) | |
| Vibration | 10 to 55 Hz Double amplitude 1.5 mm 0.06″ in the X, Y, Z axis directions respectively, 2 hours | |
| Impact resistance | 1000 m/s2(IEC60068-2-27) | |
| MaterialsMain body | Main body case: SUS440C (GT2-S1)/SUS430F (GT2-S5), Sensor head–relay connector cable: PUR, Relay amplifier: PPSU | |
| Dust boot | NBR | |
| Contact*6 | SUS304, cemented tungsten carbide | |
| Sensor head cable | Optional (connect to relay connector) | |
| Weight (not including cable)*7 | Approx. 30 g | Approx. 40 g |