| Article number | 6GK7343-1CX10-0XE0 |
| Product type designation | CP 343-1 Lean |
| Transfer rate | |
| Transfer rate | |
|
● at the 1st interface
|
10 … 100 Mbit/s |
| Interfaces | |
| Number of interfaces acc. to Industrial Ethernet | 2 |
| Number of electrical connections | |
|
● at the 1st interface acc. to Industrial Ethernet
|
2 |
|
● for power supply
|
1 |
| Type of electrical connection | |
|
● of Industrial Ethernet interface
|
RJ45 port |
|
● at the 1st interface acc. to Industrial Ethernet
|
RJ45 port |
| Type of electrical connection | |
|
● for power supply
|
2-pole plugable terminal block |
| Supply voltage, current consumption, power loss | |
| Type of voltage of the supply voltage | DC |
| Supply voltage 1 from backplane bus | 5 V |
| Supply voltage | 24 V |
| Supply voltage external | 24 V |
| Supply voltage external at DC Rated value | 24 V |
| Relative positive tolerance at DC at 24 V | 20 % |
| Relative negative tolerance at DC at 24 V | 15 % |
| Consumed current | |
|
● from backplane bus at DC at 5 V typical
|
0.2 A |
|
● from external supply voltage at DC at 24 V typical
|
0.16 A |
|
● from external supply voltage at DC at 24 V maximum
|
0.2 A |
| Power loss [W] | 5.8 W |
| Ambient conditions | |
| Ambient temperature | |
|
● for vertical installation during operation
|
0 … 40 °C |
|
● for horizontally arranged busbars during operation
|
0 … 60 °C |
|
● during storage
|
-40 … +70 °C |
|
● during transport
|
-40 … +70 °C |
| Relative humidity | |
|
● at 25 °C without condensation during operation maximum
|
95 % |
| Protection class IP | IP20 |
| Design, dimensions and weights | |
| Module format | Compact module S7-300 single width |
| Width | 40 mm |
| Height | 125 mm |
| Depth | 120 mm |
| Net weight | 0.22 kg |
| Mounting type | |
|
● S7-300 rail mounting
|
Yes |
| Performance data open communication | |
| Number of possible connections for open communication by means of SEND/RECEIVE blocks maximum | 8 |
| Amount of data | |
|
● as user data per ISO on TCP connection for open communication by means of SEND/RECEIVE blocks maximum
|
8 Kibyte |
|
● as user data per TCP connection for open communication by means of SEND/RECEIVE blocks maximum
|
8 Kibyte |
|
● as user data per UDP connection for open IE communication by means of SEND/RECEIVE blocks maximum
|
2 Kibyte |
| Number of Multicast stations | 8 |
| Performance data S7 communication | |
| Number of possible connections for S7 communication | |
|
● maximum
|
4 |
| Service | |
|
● of SIMATIC communication as server
|
Yes |
| Performance data multi-protocol mode | |
| Number of active connections with multi-protocol mode | 12 |
| Performance data PROFINET communication as PN IO controller | |
| Product function PROFINET IO controller | No |
| Performance data PROFINET communication as PN IO device | |
| Product function PROFINET IO device | Yes |
| Amount of data | |
|
● as user data for input variables as PROFINET IO device maximum
|
512 byte |
|
● as user data for input variables as PROFINET IO device maximum
|
512 byte |
|
● as user data for input variables for each sub-module as PROFINET IO device
|
240 byte |
|
● as user data for input variables for each sub-module as PROFINET IO device
|
240 byte |
|
● as user data for the consistency area for each sub-module
|
240 byte |
| Number of submodules per PROFINET IO-Device | 32 |
| Performance data telecontrol | |
| Protocol is supported | |
|
● TCP/IP
|
Yes |
| Product functions management, configuration, engineering | |
| Product function MIB support | Yes |
| Protocol is supported | |
|
● SNMP v1
|
Yes |
|
● DCP
|
Yes |
|
● LLDP
|
Yes |
| Configuration software | |
|
● required
|