| Type Designations | RSB-3601- _ _ _ – 2 _ _ – _ _ _
Ratiometric |
RSB-3601- _ _ _ – 1 1 _ – _ _ _
Analog voltage |
RSB-3601- _ _ _ – 1 2 _ – _ _ _
Analog current |
|
| Electrical Data | ||||
| Ouput signal | ratiometric to supply voltage 0.25 V
0.5 V (load >1 kΩ) |
0.1 … 10 V
(load >10 kΩ) |
4 … 20 mA
(burden < 500 Ω) |
|
| Number of channels | 1 / 2 | 1 | 1 | |
| Update rate | typical 5 | kHz | ||
| Resolution | 12 | Bit | ||
| Measuring range | 0 … 30 up to 0 … 360 (10°-steps) | ° | ||
| Absolute linearity at measuring range 360° | < 0.8 | ±% FS | ||
| Repeatability | < 0.1 | ° | ||
| Hysteresis | < 0.1 | ° | ||
| Temperature error at measuring range 360° | < 0.6 | < 1.6 | < 1.9 | ±% FS |
| Supply voltage Ub | 5 (4.5 … 5.5) | 24 (18 … 30) | 24 (18 … 30) | VDC |
| Current consumption (w/o load) | typical 15 (typ. 8 on request) per channel | mA | ||
| Reverse voltage | yes, supply lines | |||
| Short circuit protection | yes (vs. GND and supply voltage) | |||
| Insulation resistance (500 VDC) | > 10 | MΩ | ||
| Cross-section cable | 4 pole: 0.5 (AWG 20), 8 pole: 0.25 (AWG 24) | mm2 | ||
| Environmental Data | ||||
| MTTF (DIN EN ISO 13849-1
parts count method, w/o load, wc) |
356 (one-channel)
210 (per channel) partly redundant 388 (per channel) fully redundant |
107 | 105 | years years years |
| Type designations | RMB-36_ _-2_ _-44 _- _ _ _
Supply voltage 24 VDC |
|
| Electrical Data | ||
| Protocol | SSI | |
| Inputs | RS422-compatible, CLK-lines via optocoupler galvanically isolated | |
| Monoflop time ™ | 20 ±1 | µs |
| Coding | Gray, binary | |
| Update rate (internal) | 1 | kHz |
| Resolution | 16 or 18 across the entire measuring range | Bit |
| Measuring range | see ordering specifications | |
| Absolute linearity | 14 turns: < 0.036
16 turns: < 0.031 |
±% FS
±% FS |
| Repeatability | < 0.5 | ° |
| Hysteresis | < 1 | ° |
| Temperature error | < 0.1 | ±% FS |
| Supply voltage Ub | 24 (10 … 32), (5 V on request) | VDC |
| Current consumption (w/o load) | typical 10 | mA |
| Reverse voltage | yes, supply lines and outputs | |
| Short circuit protection | yes (vs. GND, max. 1 min) | |
| Ohmic load at ouputs | > 120 | Ω |
| Maximum clock rate | 1 | MHz |
| Insulation resistance (500 VDC) | > 10 | MΩ |
| Cross-section cable | 0.25 (AWG 24) | mm2 |
| Environmental Data | ||
| MTTF (DIN EN ISO 13849-1
parts count method, w/o load, wc) |
173 | Years |