| Type | RSX-79_ _-_ _ _-32_-_ _ _ |
| Output signal | 4 … 20 mA |
| Burden | ≤ 250 Ω |
| Number of channels | 1 / 2 |
| Update rate | 5 kHz |
| Measuring range | 60°, 120°, 180°, 240°, 300°, 360° |
| Absolute linearity | Measuring range < 90°: ±2 %FS, Measuring range ≥ 90°: ±1 %FS |
| Interlinearity | Measuring range < 90°: ±4 %FS, Measuring range ≥ 90°: ±2 %FS |
| Resolution | 12 bits |
| Repeatability | ≤ ±0.2° |
| Hysteresis | typ. < ±0.1°
Only measuring range 360°: typ. < 0.25° (lower hysteresis on request) |
| Temperature error | Measuring range < 90°: 200 ppm/K, Measuring range ≥ 90°: 160 ppm/K |
| Supply voltage Ub | 12/24 VDC (9 … 34 VDC) |
| Current consumption w/o load | typ. 20 mA per channel (Ub = 24 V) |
| Polarity protection | yes (supply lines) |
| Short circuit protection | yes (vs. GND and supply voltage Ub) |
| Insulation resistance (500 VDC) | ≥ 10 MΩ |
| Environmental Data | |
| Max. operational speed | 50 rpm |
| Vibration IEC 60068-2-6 | 20 g, 5 … 2000 Hz, Amax = 0.75 mm |
| Shock IEC 60068-2-27 | 50 g, 6 ms |
| Protection class ISO 20653 | IP67 / IP6K9K (connector M12: IP67) |
| Operating temperature | -40 … +85°C |
| Life | > 100 Mio. movements |
| Functional safety | Suitable for safety-relevant applications according to ISO 13849 after customer validation.
Further safety data ( DCavg…) and support for functional safety are available on request. |
| MTTF (IEC 60050) | 461 years (per channel) |
| MTTFd (EN ISO 13849-1 parts count
method, w/o load) |
923 years (per channel) |