| Type Designations | RFC-48_ _- _ _ _ – 2 _ _ – _ _ _ RFC-48_ _- _ _ _ – 1 1 _ – _ _ _ RFC-48_ _- _ _ _ – 1 2 _ – _ _ _
ratiometric voltage current |
||||
| Electrical Data | |||||
| Output signal | ratiometric to supply voltage 0.1 … 10 V 4 … 20 mA
0.25 … 4.75 V (5 … 95 %) (load >10 kΩ) (burden < 500 Ω) 0.5 … 4.5 V (10 … 90 %) (load >5 kΩ) |
||||
| Number of channels | 1 / 2 1 1 | ||||
| Diagnosis | activated (in case of error output signal is outside of the plausible signal range) | ||||
| Update rate | typical 3.4 | kHz | |||
| Resolution | 12 | bit | |||
| Measuring range | 0 … 30 up to 0 … 360, in 10°-steps | ° | |||
| Independent linearity | < 0.5 | ±% FS | |||
| Repeatability | typical < 0.1 | ° | |||
| Hysteresis at measuring range < 360° | typical < 0.1 | ° | |||
| Hysteresis at measuring range 360° | typical < 0.25 (lower hysteresis on request) | ° | |||
| Temperature error at measuring range 30 up to 170° | typical ±0,7 typical ±1,0 typical ±1,2 | % FS | |||
| Temperature error at measuring range 180 up to 360° | typical ±0,35 typical ±0,5 typical ±0,6 | % FS | |||
| Supply voltage Ub | 5 (4.5 … 5.5) 24 (18 … 30) 24 (13 … 30) | VDC | |||
| Current consumption (w/o load) | typical 12 per channel | mA | |||
| Reverse voltage | yes, supply lines and outputs | ||||
| Short circuit protection | yes (vs. GND and supply voltage) | ||||
| Insulation resistance (500 VDC) | > 10 | MΩ | |||
| Cross-section cable | 0.5 (AWG 20) | mm2 | |||
| Environmental Data | |||||
| Type Designations | RFC-48_ _- _ _ _ -2 _ _ – _ _ _
ratiometric |
RFC-48_ _- _ _ _ -3 _ _ – _ _ _
voltage |
RFC-48_ _- _ _ _ -32 _ _ – _ _ _
current |
||
| Electrical Data | |||||
| Output signal | ratiometric to supply voltage Ub 0.25 … 4.75 V (5 … 95 %)
0.5 … 4.5 V (10 … 90 %) (load >5 kΩ) |
0.25 V
0.5 V (load >10 kΩ) |
4 … 20 mA
(burden @ Ub > 13 V: < 500 Ω burden @ Ub < 13 V: < 250 Ω) |
||
| Number of channels | 1 / 2 | ||||
| Diagnosis | activated (in case of error output signal is outside | of the plausible signal range) | |||
| Update rate | typical 3.4 | kHz | |||
| Resolution | 12 | bit | |||
| Measuring range | 0 … 30 up to 0 … 360, in 10°-steps | ° | |||
| Independent linearity | < 0,5 | ±% FS | |||
| Repeatability | typical < 0,1 | ° | |||
| Hysteresis at measuring range < 360° Hysteresis at measuring range 360° | typical < 0,1
typical < 0,25 (lower hysteresis on request) |
°
° |
|||
| Temperature error at measuring range 30 and 170° | typical ±0.7 | typical ±1.0 | typical ±1.2 | % FS | |
| Temperature error at measuring range 180 and 360° | typical ±0.35 | typical ±0.5 | typical ±0.6 | % FS | |
| Supply voltage Ub | 5 (4.5 … 5.5) | 12/24 (8 … 34) | 12/24 (8 … 34) | VDC | |
| Current consumption (w/o load) | typical 12 per channel | mA | |||
| Reverse voltage | yes, supply lines and outputs | ||||
| Short circuit protection | yes (vs. GND and supply voltage) | ||||
| Insulation resistance (500 VDC) | > 10 | MΩ | |||
| Cross-section cable / lead wires | 0.5 (AWG 20) | mm2 | |||
| Environmental Data | |||||
| Operating temperature | -40 … +105
-25 … +85 with M12 connector |
-40 … +105 *
-25 … +85 with M12 connector |
-40 … +105 *
-25 … +85 with M12 connector |
°C
°C |
|
| MTTF (DIN EN ISO 13849-1
parts count method, w/o load, wc) |
99 (per channel) | 44 (per channel) | 40 (per channel) | years | |
| MTTFd (DIN EN ISO 13849-1 | 198 (per channel) | 88 (per channel) | 80 (per channel) | years | |