| Item | Single-function models | Single-function models | Green LED | Blue LED | Infrared LED |
| Model | E3X-DA@SE-S | E3X-DA@-S | E3X-DAG@-S | E3X-DAB@-S | E3X-DAH@-S |
| Light source (wavelength) | Red LED (635 nm) | Green LED (525 nm) | Blue LED (470 nm) | Infrared LED (870nm) | |
| Power supply voltage | 12 to 24 VDC ±10%, ripple (p-p) 10% max. | ||||
| Power consumption | 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC) | ||||
| Control output | Load power supply voltage: 26.4 VDC; NPN/PNP open collector; load current: 50 mA max.; residual voltage: 1 V max. | ||||
| Remote control input | No-voltage input (contact/non-contact) | — | |||
| Protection circuits | Reverse polarity for power supply connection, output short-circuit | ||||
| Super-high- speed mode | — | Operate: 48 ms, reset: 50 ms *1, *2 | |||
| High-speed mode | — | Operate/reset: 250 ms | |||
| Standard mode | Operate or reset: 1 ms | ||||
| High-resolution mode | — | Operate or reset: 4 ms | |||
| Sensitivity setting | Teaching or manual method | ||||
| Power tuning | — | Light emission power and reception gain, digital control method | |||
| Timer function | — | Select from OFF-delay, ON-delay, or one-shot timer.1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments) | |||
| Automatic power control (APC) | High-speed control method for emission current | ||||
| Zero-reset | — | Negative values can be displayed. (Threshold value is shifted.) | |||
| Initial reset | Settings can be returned to defaults as required. | ||||
| Mutual interfer- ence prevention | Possible for up to 10 Units *3 | ||||
| Display | Operation indicator (orange) | Operation indicator (orange), Power Tuning indicator (orange) | |||
| Digital display | incident level + threshold | Select from incident level + threshold or other 6 patterns | |||
| Display orientation | — | Switching between normal/reversed display is possible. | |||
| Ambient illumination (Receiver side) | Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. | ||||
| Ambient temperature range | Operating: Groups of 1 to 2 Amplifiers: -25°C to 55°C Groups of 3 to 10 Amplifiers: -25°C to 50°C Groups of 11 to 16 Amplifiers: -25°C to 45°CStorage: -30°C to 70°C (with no icing or condensation) | ||||
| Ambient humidity range | Operating and storage: 35% to 85% (with no condensation) | ||||
| Insulation resistance | 20 MΩ min. (at 500 VDC) | ||||
| Dielectric strength | 1,000 VAC at 50/60 Hz for 1 minute | ||||
| Vibration resistance | Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions | ||||
| Shock resistance | Destruction: 500 m/s2, for 3 times each in X, Y and Z directions | ||||
| Degree of protection | IEC 60529 IP50 (with Protective Cover attached) | ||||
| Connection method | Pre-wired or amplifier unit connector | ||||
| Weight (packed state) | Pre-wired model: Approx. 100 g, Amplifier unit connector model: Approx. 55 g | ||||
| Case | Polybutylene terephthalate (PBT) | ||||
| Cover | Polycarbonate (PC) | ||||
| Accessories | Instruction manual | ||||