• CP1L M30DR A 1
  • CP1L M30DR A 2
  • CP1L M30DR A 1
  • CP1L M30DR A 2

Omron PLC CP series CP1L CPU Unit CP1L-M30DR-A CP1L-M30DT-A

Series#: Omron PLC

Product Details

  • Omron PLC CP series CP1L CPU Unit CP1L-M30DR-A CP1L-M30DT-A
  • CP1L-EM” and “CP1L-EL” have complete with a Ethernet
  • Omron PLC Controller Module CP-series
  • We are First Class Omron plc dealer and omron plc distributor in China.
  • We can Supply Omron automation parts,such as Omron PLC,Omron Servo Motor,Omron HMI,Omron VFD and Omron Relay and Omron Sensor and ect.
  • 100% Original and new,In stock by Omron Automation
  • Delivery time: Ready in stock and 1 days for ship out
  • MOQ: 1pcs
Qty:

Specification

Models CP1L-M60(60 points) CP1L-M40(40 points) CP1L-M30(30 points) CP1L-L20(20 points) CP1L-L14(14 points) CP1L-L10(10 points)
CP1L-M60@@@ CP1L-M40@@@ CP1L-M30@@@ CP1L-L20@@@ CP1L-L14@@@ CP1L-L10@@@
Control method Stored program method
I/O control method Cyclic scan with immediate refreshing
Program language Ladder diagram
Function blocks Maximum number of function block definitions: 128 Maximum number of instances: 256 Languages usable in function block definitions: Ladder diagrams, structured text (ST)
Instruction length 1 to 7 steps per instruction
Instructions Approx. 500 (function codes: 3 digits)
Instruction execution time Basic instructions: 0.55 ms min. Special instructions: 4.1 ms min.
Common processing time 0.4 ms
Program capacity 10K steps 5K steps
Number of tasks 288 (32 cyclic tasks and 256 interrupt tasks)
Maximum subroutine number 256
Maximum jump number 256
Work bits 8,192 bits (512 words): W000.00 to W511.15 (W0 to W511)CIO Area: 37,504 bits (2,344 words): CIO 3800.00 to CIO 6143.15 (CIO 3800 to CIO 6143)
TR Area 16 bits: TR0 to TR15
Holding Area 8,192 bits (512 words): H0.00 to H511.15 (H0 to H511)
AR Area Read-only (Write-prohibited): 7168 bits (448 words): A0.00 to A447.15 (A0 to A447) Read/Write: 8192 bits (512 words): A448.00 to A959.15 (A448 to A959)
Timers 4,096 timer numbers: T0 to T4095
Counters 4,096 counter numbers: C0 to C4095
DM Area 32 Kwords: D0 to D32767 10 Kwords: D0 to D9999, D32000 to D32767
Data Register Area 16 registers (16 bits): DR0 to DR15
Index Register Area 16 registers (32 bits): IR0 to IR15
Task Flag Area 32 flags (32 bits): TK0000 to TK0031
Trace Memory 4,000 words (500 samples for the trace data maximum of 31 bits and 6 words.)
Memory Cassette A special Memory Cassette (CP1W-ME05M) can be mounted. Note: Can be used for program backups and auto-booting.
Clock function Supported. Accuracy (monthly deviation): -4.5 min to -0.5 min (ambient temperature: 55°C),-2.0 min to +2.0 min (ambient temperature: 25°C), -2.5 min to +1.5 min (ambient temperature: 0°C)
 Memory backup Flash memory: User programs, parameters (such as the PLC Setup), comment data, and the entire DM Area can be saved to flash memory as initial values.Battery backup: The Holding Area, DM Area, and counter values (flags, PV) are backed up by a battery.
Battery service life Service life expectancy is 5 years at 25°C, less at higher temperatures. (From 0.75 to 5 years depending on model, power supply rate, and ambient temperature.)