| Article number | 6ES7336-4GE00-0AB0 |
| SM 336, f.AI 6 X 0/4 … 20mA HART | |
| Supply voltage | |
| Rated value (DC) | 24 V |
| Reverse polarity protection | Yes |
| Load voltage L+ | |
|
● Rated value (DC)
|
24 V |
|
● Reverse polarity protection
|
Yes |
| Input current | |
| From power supply L+, typ. | 150 mA |
| from backplane bus 5 V DC, max. | 90 mA |
| Power loss | |
| Power loss, typ. | 4.5 W |
| Analog inputs | |
| Number of analog inputs | 6 |
| permissible input current for current input (destruction limit), max. | 40 mA |
| Input ranges | |
|
● Voltage
|
No |
|
● Current
|
Yes |
|
● Thermocouple
|
No |
|
● Resistance thermometer
|
No |
|
● Resistance
|
No |
| Input ranges (rated values), currents | |
|
● 0 to 20 mA
|
Yes |
|
— Input resistance (0 to 20 mA)
|
150 Ω; typ. 150 ohms max. 175 ohms |
|
● 4 mA to 20 mA
|
Yes |
|
— Input resistance (4 mA to 20 mA)
|
150 Ω; typ. 150 ohms max. 175 ohms |
| Cable length | |
|
● shielded, max.
|
1 000 m |
| Analog value generation for the inputs | |
| Integration and conversion time/resolution per channel | |
|
● Resolution with overrange (bit including sign), max.
|
16 bit; 15 bit + sign |
|
● Integration time (ms)
|
20 ms @ 50 Hz, 16.7 ms @ 60 Hz |
|
● Interference voltage suppression for interference frequency f1 in Hz
|
f=n x (f1 ±0.5 %) |
| Encoder | |
| Connection of signal encoders | |
|
● for current measurement as 2-wire transducer
|
Yes |
|
● for current measurement as 4-wire transducer
|
Yes |
| Errors/accuracies | |
| Operational error limit in overall temperature range | |
|
● Current, relative to input range, (+/-)
|
0.2 %; 40 µA |
| Basic error limit (operational limit at 25 °C) | |
|
● Current, relative to input range, (+/-)
|
0.1 % |
| Interrupts/diagnostics/status information | |
| Diagnostics function | Yes |
| Alarms | |
|
● Diagnostic alarm
|
Yes |
| Diagnoses | |
|
● Diagnostic information readable
|
Yes |
| Diagnostics indication LED | |
|
● Fail-safe operation
|
Yes |
|
● Group error SF (red)
|
Yes |
|
● Encoder supply Vs (green)
|
No |
| Potential separation | |
| Potential separation analog inputs | |
|
● between the channels
|
Yes |
|
● between the channels and backplane bus
|
Yes |
|
● between the channels and the power supply of the electronics
|
Yes |
| Isolation | |
| Isolation tested with | 370V for 1 min |
| Standards, approvals, certificates | |
| Highest safety class achievable in safety mode | |
|
● acc. to EN 954
|
4 |
|
● Performance level according to ISO 13849-1
|
e |
|
● SIL acc. to IEC 61508
|
SIL 3 |
| Connection method | |
| required front connector | 20-pin |
| Dimensions | |
| Width | 40 mm |
| Height | 125 mm |
| Depth | 120 mm |
| Weights | |
| Weight, approx. | 350 g |